Specification

Output Specification
Output Capacity (KVA )
6 Kva
Output Capacity (KW )
5.4 Kw
Output Power Factor
0.99 Power Factor
Output Phase
1 Phase
Other Output Phase
Output Voltage
230 Volt
Other Output Voltage
220 Or 240 Volt
Efficiency at Full Load
>94 %
Output Voltage Distortion
<2 %
Output Frequency (sync to mains)
50/60Hz +/- 3 Hz
Output Frequency (not synced)
60Hz +/- 0.1% for 60Hz nominal, 50Hz +/- 0.1% for 50Hz nominal
Load Crest Factor
3:1
Output Voltage THD
<2 %
Transfer Time
<0 Ms
Output Waveform type
Sine Wave
Output Connections
Hard Wire 3 wire (1PH+N+G)
Bypass
Internal Bypass (automatic & manual)
Overload Capacity
Optional
UPS Parallel Upto
Input Specification
Input Voltage
230 Volt
Other Input Voltage
Input Phase
1 Phase
Other Input Phase
Input frequency
50/60Hz +/- 3 Hz
Input Voltage Range (Output Derated)
160 - 285 Volt
Input voltage range for main operations
Input frequency Range
40 - 70 Hz
Input Power Factor
>0.99 None
Input Connections
Hard Wire 3 wire (1PH+N+G)
Input Protection
Batteries & Runtime
Approved Battery Capacity (AH)
Battery DC Bus
Maximum Charger Capacity
13 Amp.
Battery Position Option
External
Battery Type Compatibility
SMF Battery
Batteries Recharge Time upto 90%
Communication & Management
Control panel
Multi-function LCD status and control console
SNMP Management
In-Built
Power Management Software
In-Built
Interface Port(s)
DB-9 RS-232, Smart-Slot
Audible Alarm
Audible and visible alarms prioritized by severity
Audible noise at 1 meter from surface of unit
<50 Decibal
Physical
Maximum Height
220 Mm
Maximum Width
438 Mm
Maximum Depth
615 Mm
Shipping Height
490 Mm
Shipping Width
600 Mm
Shipping Depth
870 Mm
Net Weight
78 Kg
Shipping weight
88 Kg
Rack Height(U)
Colour
Environmental
Operating Temperature
0 - 40 °C
Operating Relative Humidity
0 - 95 % Rh
Operating Elevation
Storage Temperature
-10 - +40 °C
Storage Relative Humidity
0 - 95 % Rh
Storage Elevation
Compliances
Compliance
IS 16242 (Part1): 2014
Approvals
IS 16242 (Part1): 2014
Other Environmental Compliance
IS 16242 (Part1): 2014
Other Specifications
Technology
Double Conversion Online
Filtering
Full time multi-pole noise filtering : 0.3% IEEE surge let-through : zero clamping response time : meets UL 1449
Surge Protection
Yes