APC - Schneider Electric Make 3000 VA 1:1 Phase LI Smart UPS | apcups.co.in

Contact Us

Product UPS System Line Interactive UPS APC - Schneider Electric Make 3000 VA 1:1 Phase LI Smart UPS

APC - Schneider Electric Make 3000 VA 1:1 Phase LI Smart UPS

UPS System Line Interactive UPS

51448

APC Smart-UPS XL 3000VA 230V No Battery Intelligent and efficient network power protection from entry level to scaleable runtime. Ideal UPS for servers, point-of-sale, routers, switches, hubs and other network devices. Includes: CD with software, Smart UPS signalling RS-232 cable, USB cable, User manual

Model SUA3000UXI

Reset default

Specification

Output Specification
Output Capacity (VA )
3000 VA
Output Capacity (Watt )
2700 W
Output Waveform type
Sine Wave
Output Connections
IEC Sockets
Output Voltage
230 Volt
Input Specification
Input Connections
IEC Sockets
Input Power Cord Lengh
1.8 Meters
Input voltage range for main operations
151 - 302 Volt
Input Voltage
230 Volt
Batteries & Runtime
Approved Battery Capacity (AH)
17 - 100 Amp.
Battery DC Bus
48 VDC
Maximum Charger Capacity
8 W
Battery Type Compatibility
SMF Battery
Communication & Management
Control panel
LED status display
Interface Port(s)
USB
Power Management Software
Yes
Physical
Maximum Height
432 Mm
Maximum Width
196 Mm
Maximum Depth
544 Mm
Net Weight
28.64 Kg
Shipping weight
33.64 Kg
Shipping Height
559 Mm
Shipping Width
381 Mm
Shipping Depth
762 Mm
Environmental
Operating Temperature
0 - 40 °C
Operating Relative Humidity
0 - % 95
Audible noise at 1 meter from surface of unit
< 53 Decibal
Compliances
Approvals
BIS

Features

SUA3000UXI Features
Smart UPS Line Interactive Features
Availabilty
Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power.
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Temperature-compensated battery charging
Prolongs battery life by regulating the charge voltage according to battery temperature.
Power conditioning
Protects connected loads from surges, spikes, lightning, and other power disturbances.
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Disconnected battery notification
Warns when a battery is not available to provide backup power.
Boost and Trim Automatic Voltage Regulation (AVR)
Gives higher application availability by correcting low and high voltage conditions without using th
Manageability
Network manageable
Provides remote power management of the UPS over the network.
Serial connectivity
Provides management of the UPS via a serial port.
USB Connectivity
Provides management of the UPS via a USB port (not available on all models).
Audible alarms
Provides notification of changing utility power and UPS power conditions
LED status indicators
Quickly understand unit and power status with visual indicators.
Marketing Features
Avoids costly power problems by keeping your IT equipment and data protected and available
Network grade power conditioning protects from damaging surges and disruptive noise. The double conv
Peace of mind that comes with full equipment compatibility and reliability of a leader
Provides pure sine wave output which is recommended by server manufacturers using active power facto
Low operating and maintenance costs with proven reliability and intelligent battery management
Intelligent battery management, pioneered by APC, maximizes battery performance and life through int
Smarter productivity with ability to tailor to your specific application needs
Intuitive LCD interface provides clear information with the ability to configure the UPS locally wit
Save time with easy and convenient remote/network accessibility
Network manageable via serial, USB or Ethernet. Includes Powerchute® Software for convenient monitor
Safety
Safety-agency Approved
Ensures the product has been tested and approved to work safely with the connected service provider
Adoptbility
Adjustable Voltage Sensitivity
Provides the ability to adapt the UPS for optimal performance in specific power environments or gene
Adjustable Voltage-Transfer Points
Maximizes useful battery life by widening the input voltage window or tightening the output voltage
Serviceability
Battery Failure Notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
User-replaceable Batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batter
Predicitive failure notification
Provides early-warning fault analysis ensuring proactive component replacement.
Resettable circuit breaker
Easy recovery from overloads; no need to replace a fuse. (Not available on Wall Tap SKUs)

Documentation

Item Catalogue
SUA(750VA to 3000VA) IND and UXI model brochure
pdf