APC - Schneider Electric Make 5 KVA On-Line 1:1 Phase On-Line UPS | apcups.co.in

Contact Us

Support APC UPS System APC - Schneider Electric Make 5 KVA On-Line 1:1 Phase On-Line UPS

APC - Schneider Electric Make 5 KVA On-Line 1:1 Phase On-Line UPS

UPS System On Line UPS

0.00

APC Smart-UPS RC 5000VA 230V for India - No Batteries High density, double-conversion on-line power protection with scalable runtime Includes: Smart UPS signalling RS-232 cable, User manual

Model SRC5KUXI

Reset default

Specification

Output Specification
Output Capacity (KVA )
5 KVA
Output Capacity (KW )
4.5 Kw
Output Power Factor
0.9 Power Factor
Output Phase
1 Phase
Output Voltage
230 Volt
Other Output Voltage
220 Or 240 Volt
Efficiency at Full Load
> 94 %
Output Voltage Distortion
<5 %
Output Frequency (sync to mains)
50/60Hz +/- 3 Hz
Output Frequency (not synced)
60Hz +/- 0.1% for 60Hz nominal, 50Hz +/- 0.1% for 50Hz nominal
Load Crest Factor
3:1
Output Voltage THD
<2 %
Transfer Time
<0 Ms
Output Waveform type
Sine Wave
Output Connections
Hard Wire 3 wire (1PH+N+G)
Bypass
Internal Bypass (automatic & manual)
UPS Parallel Upto
2 Nos.
Input Specification
Input Voltage
230 Volt
Other Input Voltage
220 Or 240 Volt
Input Phase
1 Phase
Input frequency
50/60Hz +/- 3 Hz
Input Voltage Range (Output Derated)
100 - 285 Volt
Input voltage range for main operations
160 - 285 Volt
Input frequency Range
40 - 70 Hz
Input Power Factor
> 0.98
Input Connections
Hard Wire 3 wire (1PH+N+G)
Input Protection
Resettable Circuit Breaker
Batteries & Runtime
Approved Battery Capacity (AH)
7 - 100 Amp.
Battery DC Bus
192 VDC
Maximum Charger Capacity
10 Amp.
Battery Position Option
External
Battery Type Compatibility
SMF / Flooded Batteries
Batteries Recharge Time upto 90%
<10 Hrs.
Communication & Management
Control panel
Multi-function LCD status and control console
SNMP Management
Optional
Power Management Software
In-Built
Interface Port(s)
DB-9 RS-232, Smart-Slot
Audible Alarm
Audible and visible alarms prioritized by severity
Audible noise at 1 meter from surface of unit
<50 Decibal
Physical
Maximum Height
433 Mm
Maximum Width
134 Mm
Maximum Depth
706 Mm
Shipping Height
570 Mm
Shipping Width
275 Mm
Shipping Depth
790 Mm
Net Weight
18.8 Kg
Shipping weight
23.5 Kg
Rack Height(U)
3 U
Colour
Black
Environmental
Operating Temperature
0 - 40 °C
Operating Relative Humidity
0 - 95 % Rh
Operating Elevation
0 - 1000 Meters
Storage Temperature
-15 - °C +60
Storage Relative Humidity
0 - 95 % Rh
Storage Elevation
0 - 15000 Meters
Compliances
Compliance
IS 16242 (Part1): 2014
Approvals
BIS
Other Environmental Compliance
IS 16242 (Part1): 2014
Other Specifications
Technology
Double Conversion Online
Filtering
Full time multi-pole noise filtering : 0.3% IEEE surge let-through : zero clamping response time : meets UL 1449
Surge Protection
Yes

Features

Smart UPS On Line Features & Benefits
Serviceability
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batter
Audible alarms
Provides notification of changing utility power and UPS power conditions
Disconnected battery notification
Warns when a battery is not available to provide backup power.
Predicitive failure notification
Provides early-warning fault analysis ensuring proactive component replacement.
Protection
Generator compatible
Ensures clean, uninterrupted power to protected equipment when generator power is used.
Power conditioning
Protects connected loads from surges, spikes, lightning, and other power disturbances.
Input power factor correction
Minimizes installation costs by enabling the use of smaller generators and cabling.
Resettable circuit breaker
Easy recovery from overloads; no need to replace a fuse. (Not available on Wall Tap SKUs)
Cold-start Capable
Provides Temporary Battery Power When The Utility Power Is Out.
Safety-agency Approved
Ensures the product has been tested and approved to work safely with the connected service provider
Frequency and voltage regulation
Gives higher application availability by correcting poor frequency and voltage conditions without us
Marketing Features
Save time with easy and convenient remote/network accessibility
Network manageable via serial, USB or Ethernet. Includes Powerchute® Software for convenient monitor
Low operating and maintenance costs with proven reliability and intelligent battery management
Intelligent battery management, pioneered by APC, maximizes battery performance and life through int
Avoids costly power problems by keeping your IT equipment and data protected and available
Network grade power conditioning protects from damaging surges and disruptive noise. The double conv
Peace of mind that comes with full equipment compatibility and reliability of a leader
Provides pure sine wave output which is recommended by server manufacturers using active power facto
Adoptbility
Rack/Tower convertible
Protects the initial investment in the UPS when migrating from tower to rack-mount environment.
Plug-and-Play external batteries
Ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS.
Flash upgradeable firmware
Install maintenance releases of firmware remotely using FTP.
Manageability
InfraStruXure Manager Compatible
Enables centralized management via the APC InfraStruXure Manager.
SmartSlot
Customize UPS capabilities with management cards.
Network manageable
Provides remote power management of the UPS over the network.
Serial connectivity
Provides management of the UPS via a serial port.
LED status indicators
Quickly understand unit and power status with visual indicators.
Availabilty
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Temperature-compensated battery charging
Prolongs battery life by regulating the charge voltage according to battery temperature.
Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power.
Scalable runtime
Allows additional run time to be quickly added as needed.
Automatic internal bypass
Supplies utility power to the connected loads in the event of a UPS power overload or fault.
SRC5KUXI Features

Documentation

Item Catalogue
APC - SRC5K/6K Catalog
pdf
Item Manuals and Warranties
APC - SRC5K/6K
pdf

Options

Services

© Copyright 2005 | apcups.co.in. All right reserved.