APC - Schneider Electric Make 750 VA LI Smart UPS (Internal Batteries) | apcups.co.in

Contact Us

Support APC UPS System APC - Schneider Electric Make 750 VA LI Smart UPS (Internal Batteries)

APC - Schneider Electric Make 750 VA LI Smart UPS (Internal Batteries)

UPS System Line Interactive UPS

20107.2

APC Smart-UPS 750VA USB & Serial 230V, India Specific Intelligent and efficient network power protection from entry level to scaleable runtime. Ideal UPS for servers, point-of-sale, routers, switches, hubs and other network devices. Includes: CD with software, Smart UPS signalling RS-232 cable, USB cable, User manual

Model SUA750I-IN

Reset default

Specification

Output Specification
Output Capacity (VA )
750 VA
Output Capacity (Watt )
500 W
Output Waveform type
Sine Wave
Output Connections
IEC Sockets
Output Voltage
230 Volt
Input Specification
Input Connections
IEC Sockets
Input voltage range for main operations
151 - 302 Volt
Input Voltage
230 Volt
Batteries & Runtime
Battery Position Option
Internal
Battery DC Bus
24 VDC
Internal Battery Capacity (VAH)
168 VAH
Battery Type Compatibility
SMF Battery
Communication & Management
Control panel
LED status display
Interface Port(s)
USB
Power Management Software
In-Built
Physical
Maximum Height
157 Mm
Maximum Width
137 Mm
Maximum Depth
361 Mm
Net Weight
13.18 Kg
Shipping weight
14.55 Kg
Shipping Height
290 Mm
Shipping Width
270 Mm
Shipping Depth
500 Mm
Colour
Black
Environmental
Operating Temperature
0 - 40 °C
Operating Relative Humidity
0 - 95 %
Audible noise at 1 meter from surface of unit
< 41 Decibal
Compliances
Approvals
BIS

Features

SUA750I-IN Features
General Features
Battery Replacement Without Tools
Enables fast battery replacement, lowering Mean Time to Repair (MTTR).
Front-Access Servicing
Simplifies installation and UPS maintenance while minimizing space requirements.
Smart UPS Line Interactive Features
Availabilty
Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power.
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Temperature-compensated battery charging
Prolongs battery life by regulating the charge voltage according to battery temperature.
Power conditioning
Protects connected loads from surges, spikes, lightning, and other power disturbances.
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Disconnected battery notification
Warns when a battery is not available to provide backup power.
Boost and Trim Automatic Voltage Regulation (AVR)
Gives higher application availability by correcting low and high voltage conditions without using th
Manageability
Network manageable
Provides remote power management of the UPS over the network.
Serial connectivity
Provides management of the UPS via a serial port.
USB Connectivity
Provides management of the UPS via a USB port (not available on all models).
Audible alarms
Provides notification of changing utility power and UPS power conditions
LED status indicators
Quickly understand unit and power status with visual indicators.
Marketing Features
Avoids costly power problems by keeping your IT equipment and data protected and available
Network grade power conditioning protects from damaging surges and disruptive noise. The double conv
Peace of mind that comes with full equipment compatibility and reliability of a leader
Provides pure sine wave output which is recommended by server manufacturers using active power facto
Low operating and maintenance costs with proven reliability and intelligent battery management
Intelligent battery management, pioneered by APC, maximizes battery performance and life through int
Smarter productivity with ability to tailor to your specific application needs
Intuitive LCD interface provides clear information with the ability to configure the UPS locally wit
Save time with easy and convenient remote/network accessibility
Network manageable via serial, USB or Ethernet. Includes Powerchute® Software for convenient monitor
Safety
Safety-agency Approved
Ensures the product has been tested and approved to work safely with the connected service provider
Adoptbility
Adjustable Voltage Sensitivity
Provides the ability to adapt the UPS for optimal performance in specific power environments or gene
Adjustable Voltage-Transfer Points
Maximizes useful battery life by widening the input voltage window or tightening the output voltage
Serviceability
Battery Failure Notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
User-replaceable Batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batter
Predicitive failure notification
Provides early-warning fault analysis ensuring proactive component replacement.
Resettable circuit breaker
Easy recovery from overloads; no need to replace a fuse. (Not available on Wall Tap SKUs)

Documentation

Item Catalogue
APC_SULI_SUA I Net Series
pdf

Options

Services

© Copyright 2005 | apcups.co.in. All right reserved.