Price: 63130

MRP 94046 You save 30916

APC Easy UPS On-Line SRV 5000VA RT 230V India - External Battery Pack
High quality, Double-conversion On-line UPS designed for essential power protection needs even in the most unstable power conditions
Includes: Basic UPS signalling RS-232 cable, CD with software, Rack mounting brackets, Stabilization/wall mounting feet, USB cable, User manual
Model SRV5KL-IN

Reset default

Specification

Output Specification
Output Capacity (KVA )
5KVA
Output Capacity (KW )
5KW
Output Power Factor
Power Factor
Output Phase
1Phase
Output Voltage
230Volt
Other Output Voltage
Volt
Efficiency at Full Load
>94%
Output Voltage Distortion
<2%
Output Frequency (sync to mains)
50/60Hz +/- 3 Hz
Output Frequency (not synced)
60Hz +/- 0.1% for 60Hz nominal, 50Hz +/- 0.1% for 50Hz nominal
Load Crest Factor
3:1
Output Voltage THD
<2%
Transfer Time
<0ms
Output Waveform type
Sine Wave
Output Connections
Hard Wire 3 wire (1PH+N+G)
Bypass
Internal Bypass (automatic & manual)
UPS Parallel Upto
4 Nos.
Input Specification
Input Voltage
230Volt
Other Input Voltage
Volt
Input Phase
1Phase
Input frequency
50/60Hz +/- 3 Hz
Input Voltage Range (Output Derated)
100-280Volt
Input voltage range for main operations
168-280Volt
Input frequency Range
40-70Hz
Input Power Factor
>0.99
Input Connections
Hard Wire 3 wire (1PH+N+G)
Batteries & Runtime
Approved Battery Capacity (AH)
7 - 65 Amp.
Battery DC Bus
192 - 240 VDC
Maximum Charger Capacity
4Amp.
Battery Position Option
External
Battery Type Compatibility
SMF Battery
Communication & Management
Control panel
Multi-function LCD status and control console
SNMP Management
Optional
Power Management Software
In-Built
Interface Port(s)
DB-9 RS-232, Smart-Slot
Audible Alarm
Audible and visible alarms prioritized by severity
Audible noise at 1 meter from surface of unit
<55Decibal
Physical
Maximum Height
220 Mm
Maximum Width
438 Mm
Maximum Depth
615 Mm
Shipping Height
240 Mm
Shipping Width
600 Mm
Shipping Depth
760 Mm
Net Weight
15 Kg
Shipping weight
18 Kg
Rack Height(U)
2 U
Colour
Black
Environmental
Operating Temperature
0 - 40 °C
Operating Relative Humidity
0 - 95 % Rh
Operating Elevation
0-3000Meters
Storage Temperature
-10 - +40 °C
Storage Relative Humidity
0 - 95 % Rh
Storage Elevation
0 - 15000 Meters
Compliances
Compliance
IS 16242 (Part1): 2014
Approvals
BIS
Other Environmental Compliance
IS 16242 (Part1): 2014
Other Specifications
Technology
Double Conversion Online
Filtering
Full time multi-pole noise filtering : 0.3% IEEE surge let-through : zero clamping response time : meets UL 1449
Surge Protection
Yes

Features

SRV5KRIL-IN Features
General Features
Automatic internal bypass
Supplies utility power to the connected loads in the event of a UPS power overload or fault.
Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power.
ECO Mode
Operating mode that by-passes unused electrical components in good power conditions to achieve high
Input power factor correction
Minimizes installation costs by enabling the use of smaller generators and cabling.
Intelligent SmartSlot
Mini slot supports various optional management cards which provide basic or essential monitoring, ma
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
LCD Graphics Display
Text and mimic diagrams that display modes of operation, system parameters and alarms.
Rack/Tower convertible
Protects the initial investment in the UPS when migrating from tower to rack-mount environment.
EPO
Attach the device to an Emergency Power Off (EPO) system so that power can be turned off in an emerg
Hard Wire Input
UPS requires a hard wire input in order to deliver maximum output wattage to protected equipment
Easy UPS On Line Features
Features
ECO Mode
Operating mode that by-passes unused electrical components in good power conditions to achieve high
Generator Compatibility
Allows you to recharge your battery while on generator power.
Input power factor correction
Minimizes installation costs by enabling the use of smaller generators and cabling.
Safety-agency Approved
Ensures the product has been tested and approved to work safely with the connected service provider
High efficiency
High efficiency rates that remain stable even at lower operating power levels
Pure sine wave output on battery
Simulates utility power to provide the highest degree of compatibility for active PFC (power factor
Management Software
Allows you to easily monitor your utility power and manage your UPS.
Double conversion on-line topology
Guarantees a consistently high level of power quality. Any disturbances on the distribution waveform
Allows the user to manage the UPS functions, schedule automatic shutdown and monitor the power grid occurrences through an interactive interface that ensures an easy and intuitive monitoring.
Management Software
Manageability
Serial connectivity
Provides management of the UPS via a serial port.
Network manageable
Provides remote power management of the UPS over the network.
LCD Graphics Display
Text and mimic diagrams that display modes of operation, system parameters and alarms.
LED Indicators
Provide easy-to-read status of the unit and utility power conditions.
SmartSlot
Customize UPS capabilities with management cards.
Serviceability
Disconnected battery notification
Warns when a battery is not available to provide backup power.
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Audible alarms
Provides notification of changing utility power and UPS power conditions
Predicitive failure notification
Provides early-warning fault analysis ensuring proactive component replacement.
Availabilty
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.

Documentation

Item Catalogue
Easy UPS On-Line_SRV5KRIL-IN
pdf
Item Manuals and Warranties
User Manual APC Make 5 KVA On-Line UPS SRV5KRIL-IN
pdf

Options

Services

© Copyright 2005 | apcups.co.in. All right reserved.